MIL-PRF-8565/15A
TABLE I. Qualification inspection and conformance inspection of batteries.
Qualification inspection
Conformance inspection
Test
Examinations and
Group
Group B
Sample
number
tests
Test
Requirement
A
sample
number
paragraph
paragraph
sample
number
1/
1/
1
1
2
1
2
3
100%
INCOMING
1
X
X
X
3.8.1(G)
4.5.1(G)
X
X
X
INSPECTION
VISUAL AND
3.5 (S), 3.6 (S),
2
MECHANICAL
X
X
X
3.8.2 (G)
4.5.2 (G)
X
X
X
EXAMINATION
table II (G)
DIMENSIONS AND
3
X 2/
X 2/
X
X
X
X
Reqmt 2 (N), 3.8.3 (G)
4.5.3 (G)
WEIGHT
DIELECTRIC
3.7 (G),
STRENGTH AND
4
X 2/
X
X
4.5.4 (G)
X
X
X
3.8.4 (G)
INSULATION
RESISTANCE TEST
STRENGTH OF VENT
3.7 (G),
5
X 2/
X
X
X
X
X
4.5.5 (G)
TUBES TEST
3.8.5 (G)
ELECTRICAL TEST
6
X
X
X
--
4.5.6 (S)
X
X
PREPARATION
Reqmt 3 (N),
CAPACITY
7
X
X
X
3.8.6 (S),
4.5.7 (S)
X
X
X
DISCHARGE
Reqmt 1 of table III (S)
CONSTANT
3.7 (G), 3.8.7 (S),
8
VOLTAGE
X
X
Reqmt 4 of table III
4.5.8 (G)
X
X
DISCHARGE
(G)
3.7 (G),
STRENGTH OF
4.5.9 (G)
X
9
3.8.8 (G)
RECEPTACLE TEST
Reqmt 4 (N),
10
CYCLING TEST
X
4.5.10 (S)
X
3.8.9 (S),
Reqmt 1 of table III (S)
CAPACITY
3.8.6 (S), Reqmt 2 of
11
X
4.5.11 (S)
DISCHARGE AT 49
table III (S)
°C (120 °F)
CHARGE AND
3.8.6 (S), Reqmt 3 of
DISCHARGE TEST
4.5.12 (S)
X
12
X
table III (S)
AT LOW
TEMPERATURE
DISCHARGE WHILE
3.5.9 (G), Reqmt 5 of
13
X
4.5.13 (G)
X
INVERTED
table III (G)
3.5.9 (G),
14
ALTITUDE TEST
X
4.5.14 (G)
X
3.7 (G),
3.8.10 (G)
SHOCK TEST (BASIC
3.7 (G),
15
X
4.5.15 (G)
DESIGN)
3.8.10 (G)
TEMPERATURE
3.7 (G)
16
X
4.5.16 (G)
X
SHOCK TEST
3.8.10 (G)
TEMPERATURE
3.7 (G),
17
RISE AND FLOAT
X
3.8.11 (G),
4.5.17 (S)
X
TEST
Reqmt 1 of table III (S)
3.8.10 (G),
BATTERY GAS
4.5.18 (G)
X
18
3.8.12 (G)
EMISSION TEST
4
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.