MIL-PRF-8565/4D (AS)
Step
Sample
Discharge
Load current
Discharge time
temperature (°C)
number
(amperes)
(seconds)
10
1
1, 2, 3
25
40
110
24
0.1
65
480
24
2
1
-29
40
10
24
110
65
0.1
24
50
10
3
2
-18
40
110
24
0.1
65
180
24
10
4
3
0
40
110
24
0.1
65
300
24
5
1
55
40
10
24
110
65
0.1
24
480
FIGURE 5. Aircraft emergency load requirements.