MIL-PRF-8565/5B(AS)
3.8.7 Constant voltage discharge. Delete the first sentence and insert: "The battery shall
produce not less than the current specified below after being tested in accordance with 4.5.8."
Current
Current
Current
Temperature
Current
Average
(amperes) at
current
(amperes)
(amperes)
(amperes)
at 5
at 15
at 30
0.3 seconds
over the
total 60
seconds
seconds
seconds
seconds
Room
875
830
750
700
684
temperature
(see 4.4.1)
-26.0 ± 2.0°C
625
580
500
420
430
4.5.10 Cycling test. In the third sentence, change "2.0-hour" to "4.0-hour".
6.3 Add the following paragraph:
"6.20 PIN supersession data. PIN supersession information and cross-references are
indicated below:
"D8565/5-1 supersedes M83769/5-1 and M83769/5-2.
"D8565/5-2 supersedes M83769/1-1 and M83769/6-2."