MIL-PRF-49450/6B(CR)
REQUIREMENTS:
Nomenclature:
Battery, Rechargeable, Cell
Rated Capacity:
3.6 ampere-hours
Voltage (Nominal)
1.2 volts
Discharge
Cut Off
Capacity (AH)
Test
Rate (Amps)
Voltage (V)
Minimum
Maximum
Capacity
5.5
0.95
3.6
4.4
Cycle Life
Normal Rate
5.5
0.95
3.0
4.4
1.831/
High Rate
55.0
0.60
---
Vibration
1.1
1.00
3.6
---
Temperature Shock
5.5
0.95
3.6
---
Altitude
5.5
0.95
2.8
---
Humidity and Charge
5.5
0.95
2.4
3.7
Retention
High Rate
55.0
0.50
1.6
---
Discharge and
Low Temperature1/
High Rate
55.0
0.50
2.3
3.7
Discharge and
Operating Position1/
NOTES:
1/ Discharge on cycling test limited to 2 minutes.
Changes from previous issue. Marginal notation are not used in this revision to identify changes
with respect to the previous issue due to the extent of the changes.
Custodian
Preparing Activity:
Army-CR
Army-CR
(Project 6140-A834)
3